Short answer: IEC 60335-1 is the general electrical-safety standard for household and similar electrical appliances. It is never used alone: it is always applied together with a relevant Part 2 that adds or modifies requirements for the specific product. For a gas appliance with electrical parts, that companion is IEC 60335-2-102 (gas, oil and solid-fuel appliances), which is applied alongside the gas product standard (EN 30 for cookers, EN 26 for water heaters, EN 15502 for boilers). The gas standard covers combustion and gas safety; IEC 60335 covers the electrical risks. Together they support the CE technical file under the Gas Appliances Regulation and the Low Voltage framework.

What IEC 60335-1 Covers

  • Protection against access to live parts and against electric shock;
  • Input power and current, heating and temperature limits in normal use;
  • Leakage current and electric strength (dielectric withstand / hipot) at the test temperature;
  • Moisture resistance, insulation resistance and electric strength after a damp treatment;
  • Overload of transformers and associated circuits, stability and mechanical hazards, mechanical strength;
  • Construction, internal wiring, components, supply connection and external flexible cords;
  • Terminals for external conductors, protective earthing, screws and joints, creepage distances and clearances;
  • Resistance to heat and fire, resistance to rusting, and abnormal operation tests.

These are written as clauses within Part 1; the Part 2 standard states which clauses apply, which are modified, and which additional tests are required. Where Part 1 and Part 2 differ, Part 2 takes precedence.

Part 1 and Part 2: How They Fit

LayerRole
IEC 60335-1General, common electrical-safety requirements for all appliances in the series
IEC 60335-2-102Particular requirements for gas, oil and solid-fuel-burning appliances having electrical connections
Gas product standardEN 30 / EN 26 / EN 15502 — combustion, gas tightness, heat input, flue performance

A common error is testing to IEC 60335-1 alone and assuming the appliance is certified. Part 1 alone is not sufficient; the applicable Part 2 and the gas standard must also be covered.

The Core Electrical Tests

TestPurpose
Earth continuityConfirms the protective earth path between accessible metal parts and the earthing terminal has low resistance (Class I appliances)
Insulation resistanceMeasures resistance between live parts and accessible surfaces after the damp treatment
Electric strength (hipot)Applies a high test voltage (set by the standard according to basic, supplementary or reinforced insulation) for a defined time without breakdown
Leakage currentMeasures current that could flow through a person at operating temperature; limits depend on the appliance class and type
Abnormal operationRuns fault conditions (locked rotor, failed components) to confirm no fire or electric-shock hazard

The exact test voltages and leakage limits are read from the standard’s tables for the relevant insulation class; they should not be quoted from memory or copied from a different appliance.

Class I vs Class II

  • Class I: protection relies on basic insulation plus a protective earth conductor; metal gas and water components are bonded to earth, and the multi-station-qc-upgrade-integrated-stove-plant/" title="Production Line">production line must test earth continuity.
  • Class II: protection relies on double or reinforced insulation with no protective earth; the appliance is marked accordingly and insulation/hipot requirements are more demanding.
  • Class III: supplied at safety extra-low voltage (SELV); less common for high-power gas appliances.

Division of Labour Between the Standards

Gas standard (EN 30 / 26 / 15502)IEC 60335 (Part 1 + 2-102)
Gas tightness, heat input, combustion (CO), flame stabilityProtection against electric shock, live parts
Flame-failure device timing, flue performanceHeating, insulation, hipot, leakage current
Thermal efficiency, rational use of energyMechanical strength, abnormal operation, fire resistance
Gas marking and categoriesWiring, components, earthing, cords

An electrical component fitted to a gas appliance (ignition module, fan, controller, solenoid) must satisfy both worlds: it must function safely in the combustion test and meet the electrical-safety requirements in the IEC test.

Where This Sits in CE Marking

  • Gas appliances placed on the EU market fall under the Gas Appliances Regulation (EU) 2016/426; the electrical risks are addressed within that assessment using the IEC 60335 series rather than a separate CE mark.
  • Appliances outside the gas regulation may use the Low Voltage Directive 2014/35/EU and EMC Directive; the exact route depends on the product.
  • The test reports and Declarations of Conformity are kept in the technical file, which is the evidence a market-surveillance authority will request.

On the Production Line

Type-test certification proves the design; the factory must also confirm that every unit is electrically safe. A production electrical-safety station typically performs a quick earth-continuity, hipot (and, where required, insulation/leakage) check in seconds, locks the line if a unit fails, and logs the result against the serial number. This is the “routine test” counterpart to the type tests and is covered in detail in the K cluster. Wanhe can integrate the electrical-safety station with the gas performance bench so a cooker passes both gas and electrical checks and a single serial-numbered record covers both.

How to Navigate the Standard

IEC 60335-1 is organised into numbered clauses that follow the logic of a safety assessment, rather than grouped by component. Early clauses cover definitions, general test conditions and classification; the middle clauses work through the hazards (input, heating, leakage, moisture, transformers, stability, mechanical strength, abnormal operation); and the later clauses cover construction and connections (wiring, components, cords, terminals, earthing, screws) and finally creepage distances, heat/fire resistance and rusting. The annexes add supporting material such as the routine (production-line) test guidance, measurement circuits and explanatory notes. When reading it for a gas appliance, always read each clause through the lens of Part 2-102, which explicitly says “this clause does not apply”, “this clause is modified as follows” or adds an extra test. Engineers who read Part 1 without applying those Part 2 modifications routinely run the wrong test or apply a limit that does not exist for their product. Keep Part 1, Part 2-102 and the gas standard open together so the test plan and the conformity file agree from the first prototype onward.

Common Mistakes

  • Testing to IEC 60335-1 without the applicable Part 2 (2-102);
  • Assuming the gas standard covers the electrical risks (it does not);
  • Using hipot voltages or leakage limits from another product class;
  • Forgetting earth-continuity on Class I production units;
  • Keeping type-test reports but running no routine electrical tests on the line;
  • Applying separate CE marks for risks that should be covered within the Gas Appliances Regulation.

Need gas and electrical tests on one production line?

Tell Wanhe your appliance, class (I/II) and target markets. We will integrate an electrical-safety routine station with the gas test bench and provide a quotation within 24 hours.

Email: wanhe1718@gmail.com  |  WhatsApp: +86 18307609558  |  Zhongshan (Xiaolan), Guangdong, China

About WANHE TESTING — Zhongshan Wanhe Test Equipment Development Co., Ltd. is a factory-direct B2B manufacturer of custom gas cooker and gas-appliance-test-bench/" title="gas appliance test bench">gas appliance test benches, water heater and wall-hung boiler test rigs, environmental chambers, range hood testers and fatigue machines. CE / ISO 9001 / IEC / EN / GB / RoHS compliant, with custom design in 7–15 days and equipment delivered to manufacturers in 30+ countries.

Published: 2026-10 | Category: Gas Appliance Standards | Cluster E · Article 8