What IEC 60335-1 Covers
- Protection against access to live parts and against electric shock;
- Input power and current, heating and temperature limits in normal use;
- Leakage current and electric strength (dielectric withstand / hipot) at the test temperature;
- Moisture resistance, insulation resistance and electric strength after a damp treatment;
- Overload of transformers and associated circuits, stability and mechanical hazards, mechanical strength;
- Construction, internal wiring, components, supply connection and external flexible cords;
- Terminals for external conductors, protective earthing, screws and joints, creepage distances and clearances;
- Resistance to heat and fire, resistance to rusting, and abnormal operation tests.
These are written as clauses within Part 1; the Part 2 standard states which clauses apply, which are modified, and which additional tests are required. Where Part 1 and Part 2 differ, Part 2 takes precedence.
Part 1 and Part 2: How They Fit
| Layer | Role |
|---|---|
| IEC 60335-1 | General, common electrical-safety requirements for all appliances in the series |
| IEC 60335-2-102 | Particular requirements for gas, oil and solid-fuel-burning appliances having electrical connections |
| Gas product standard | EN 30 / EN 26 / EN 15502 — combustion, gas tightness, heat input, flue performance |
A common error is testing to IEC 60335-1 alone and assuming the appliance is certified. Part 1 alone is not sufficient; the applicable Part 2 and the gas standard must also be covered.
The Core Electrical Tests
| Test | Purpose |
|---|---|
| Earth continuity | Confirms the protective earth path between accessible metal parts and the earthing terminal has low resistance (Class I appliances) |
| Insulation resistance | Measures resistance between live parts and accessible surfaces after the damp treatment |
| Electric strength (hipot) | Applies a high test voltage (set by the standard according to basic, supplementary or reinforced insulation) for a defined time without breakdown |
| Leakage current | Measures current that could flow through a person at operating temperature; limits depend on the appliance class and type |
| Abnormal operation | Runs fault conditions (locked rotor, failed components) to confirm no fire or electric-shock hazard |
The exact test voltages and leakage limits are read from the standard’s tables for the relevant insulation class; they should not be quoted from memory or copied from a different appliance.
Class I vs Class II
- Class I: protection relies on basic insulation plus a protective earth conductor; metal gas and water components are bonded to earth, and the multi-station-qc-upgrade-integrated-stove-plant/" title="Production Line">production line must test earth continuity.
- Class II: protection relies on double or reinforced insulation with no protective earth; the appliance is marked accordingly and insulation/hipot requirements are more demanding.
- Class III: supplied at safety extra-low voltage (SELV); less common for high-power gas appliances.
Division of Labour Between the Standards
| Gas standard (EN 30 / 26 / 15502) | IEC 60335 (Part 1 + 2-102) |
|---|---|
| Gas tightness, heat input, combustion (CO), flame stability | Protection against electric shock, live parts |
| Flame-failure device timing, flue performance | Heating, insulation, hipot, leakage current |
| Thermal efficiency, rational use of energy | Mechanical strength, abnormal operation, fire resistance |
| Gas marking and categories | Wiring, components, earthing, cords |
An electrical component fitted to a gas appliance (ignition module, fan, controller, solenoid) must satisfy both worlds: it must function safely in the combustion test and meet the electrical-safety requirements in the IEC test.
Where This Sits in CE Marking
- Gas appliances placed on the EU market fall under the Gas Appliances Regulation (EU) 2016/426; the electrical risks are addressed within that assessment using the IEC 60335 series rather than a separate CE mark.
- Appliances outside the gas regulation may use the Low Voltage Directive 2014/35/EU and EMC Directive; the exact route depends on the product.
- The test reports and Declarations of Conformity are kept in the technical file, which is the evidence a market-surveillance authority will request.
On the Production Line
Type-test certification proves the design; the factory must also confirm that every unit is electrically safe. A production electrical-safety station typically performs a quick earth-continuity, hipot (and, where required, insulation/leakage) check in seconds, locks the line if a unit fails, and logs the result against the serial number. This is the “routine test” counterpart to the type tests and is covered in detail in the K cluster. Wanhe can integrate the electrical-safety station with the gas performance bench so a cooker passes both gas and electrical checks and a single serial-numbered record covers both.
How to Navigate the Standard
IEC 60335-1 is organised into numbered clauses that follow the logic of a safety assessment, rather than grouped by component. Early clauses cover definitions, general test conditions and classification; the middle clauses work through the hazards (input, heating, leakage, moisture, transformers, stability, mechanical strength, abnormal operation); and the later clauses cover construction and connections (wiring, components, cords, terminals, earthing, screws) and finally creepage distances, heat/fire resistance and rusting. The annexes add supporting material such as the routine (production-line) test guidance, measurement circuits and explanatory notes. When reading it for a gas appliance, always read each clause through the lens of Part 2-102, which explicitly says “this clause does not apply”, “this clause is modified as follows” or adds an extra test. Engineers who read Part 1 without applying those Part 2 modifications routinely run the wrong test or apply a limit that does not exist for their product. Keep Part 1, Part 2-102 and the gas standard open together so the test plan and the conformity file agree from the first prototype onward.
Common Mistakes
- Testing to IEC 60335-1 without the applicable Part 2 (2-102);
- Assuming the gas standard covers the electrical risks (it does not);
- Using hipot voltages or leakage limits from another product class;
- Forgetting earth-continuity on Class I production units;
- Keeping type-test reports but running no routine electrical tests on the line;
- Applying separate CE marks for risks that should be covered within the Gas Appliances Regulation.
Need gas and electrical tests on one production line?
Tell Wanhe your appliance, class (I/II) and target markets. We will integrate an electrical-safety routine station with the gas test bench and provide a quotation within 24 hours.
Email: wanhe1718@gmail.com | WhatsApp: +86 18307609558 | Zhongshan (Xiaolan), Guangdong, China
About WANHE TESTING — Zhongshan Wanhe Test Equipment Development Co., Ltd. is a factory-direct B2B manufacturer of custom gas cooker and gas-appliance-test-bench/" title="gas appliance test bench">gas appliance test benches, water heater and wall-hung boiler test rigs, environmental chambers, range hood testers and fatigue machines. CE / ISO 9001 / IEC / EN / GB / RoHS compliant, with custom design in 7–15 days and equipment delivered to manufacturers in 30+ countries.