Short answer: The operator interface should make the correct action the obvious one. It shows the model and serial, the stage the test has reached, the live reading and the limit, and a clear pass or fail; if a unit fails, it states which test failed and why. The screen should keep the operator away from the hazard, not require a judgement about whether a reading is safe, and it should not allow a failed unit to be cleared without a repair and a re-test. The controls should be limited, large and consistent, and the operator should be able to run the station with a short, repeatable sequence. The HMI presents information but does not own the safety; the PLC keeps the interlocks, so the screen should never be the only path that holds the gate.

What the Screen Should Show

ItemPurposeDetail
Model / serialConfirm the unitAfter scan
StageWhere the test isSequence progress
Reading / limitCurrent valueUnit and basis
ResultPass or failClear colour and text
Failure reasonWhat to repairSpecific test

Clarity and Safety

The operator should not have to interpret a raw value; the screen should compare it against the limit and give the result. The layout should be consistent at every station, so an operator moving between positions sees the same sequence and the same symbols. The display should not rely on colour alone for a safety message, and text should be large enough to read from the working position. Keeping the operator away from the flame and gas connections is part of the station design in G1, and the HMI supports that by allowing the test to run without reaching into the station.

Controls and Limits

  • Controls should be few and large, with clear start, stop and reset;
  • A reset must not clear a failure without a repair and a retest;
  • Manual overrides should be limited and logged, as in G7;
  • Stations should be protected from accidental input and repeated pressing.

Repeated reset is the behaviour the interface should discourage, since it cycles the gas and can fill the chamber. The station should show the failure reason and route the unit to repair rather than inviting another reset. These safety rules mirror those described for burner ignition and boiler lockout.

Practical Checks

  1. Run the full sequence and confirm the stage and reading are clear at each step;
  2. Induce a failure and confirm the specific reason, not only a red light;
  3. Confirm a failed unit cannot be cleared without a retest;
  4. Check the screen can be read from the working position and in a noisy, busy line;
  5. Have a new operator run it after a short instruction to confirm the sequence.

The HMI reports the values that the PLC and MES use, described in G5, and it should display the calibration status so an out-of-calibration station is not run, covered in G9. The common errors are to crowd the screen with data, to require the operator to judge whether a value is safe, or to add controls that effectively clear a failed unit. A simple interface that is tested with a new operator is the practical standard.

Following One Station Cycle on the Screen

At the start of the cycle the screen shows the scanned serial and the model and waits for the operator to confirm; the station cannot start until the serial is valid. When the sequence begins, the display moves through the stages in order and shows each live reading beside its limit, with the unit and the basis so the operator does not have to interpret a raw number. At the combustion stage the screen shows the current CO and the flame condition, and at the end it gives a single clear pass or fail. If the unit fails, the screen names the specific test and the value that was out of limit, which tells the repair station what to correct rather than presenting a generic red alarm. The operator’s role throughout is to load the unit, confirm the serial and follow the screen; the judgement about safety is made by the PLC against the fixed limits, and the display is a presentation of that decision rather than a tool that asks the operator to decide.

How the Screen Helps Under Pressure

  • A consistent layout and a fixed sequence at every station reduce the steps an operator must remember;
  • Large, few controls and clear colour and text together make a failure readable from the working position;
  • The reset does not clear a failure, so the unit is routed to repair and retested rather than cycled repeatedly;
  • The calibration status is shown, so an overdue station is not run and its results are not trusted;
  • A new operator can run the sequence after a short instruction, which is the clearest practical acceptance test.

When the line is under pressure, the HMI is the point at which the pressure either forces a shortcut or is stopped by the process; a screen that makes the failed state explicit and keeps the gate closed removes the temptation to work around it. Crowded screens, raw values that require interpretation, and controls that effectively clear a failed unit are the three failures that most often appear when an interface is rushed into service without testing it with a new operator.

How the Interface Handles a Faulty Reading

An instrument does not always fail by giving a value outside the limit; it can also lose its reading, report an impossible value, or indicate that it is no longer calibrated, and the screen should treat these as distinct conditions rather than displaying a generic fault. A missing or impossible reading is an incomplete test, and the interface must show that the measurement cannot be used while the station holds the unit rather than passing it on the last valid number. A calibration warning should visibly prevent the station from running and explain why, so an overdue instrument cannot be used by mistake. Presenting these conditions clearly keeps the operator from guessing whether a blank or a strange value is a failure; the screen gives a defined state for each, and the PLC holds the gate behind it. The wording of these messages should be consistent with the ordinary failure messages, so that an out-of-limit reading, a missing reading and an out-of-calibration instrument are all shown as reasons the unit cannot be released, but with the specific cause identified. This also supports the repair station, because an instrument fault rather than an appliance fault is shown for what it is and the unit is not worked on for a defect it does not have. The interface is then acting as a reliable interpreter of the station’s state: it never asks the operator to decide safety, it never allows an incomplete measurement to be treated as a pass, and it makes the reason for every hold explicit. Testing these three conditions during commissioning, rather than only the ordinary pass and fail, is what keeps a strange or missing reading from becoming an unexplained release.

Need clear operator screens?

Wanhe test benches and EOL stations provide clear stage, reading and failure displays, with PLC-based safety and a controlled retest. Tell us your sequence for a quotation within 24 hours.

Email: wanhe1718@gmail.com  |  WhatsApp: +86 18307609558  |  Zhongshan (Xiaolan), Guangdong

About WANHE TESTING — Zhongshan Wanhe Test Equipment is a factory-direct B2B manufacturer of custom gas cooker and appliance test benches, water heater and boiler rigs, environmental chambers, range hood testers and fatigue machines. CE / ISO 9001 / IEC / EN / GB / RoHS, custom design in 7–15 days, delivered to 30+ countries.